Applications
The Axicon 12000 series of two-dimensional barcode verifiers is intended for the verifying of Data Matrix, QR Code, GS1 DataMatrix, GS1 QR Code, GS1 DataBar, PDF and micro-PDF codes. Some models can also verify EAN/UPC, GS1-128 and ITF-14 codes, depending on their size. They are suitable for verifying symbols appearing on product packaging, promotional advertising, and literature, and the 12800 is specially designed for verifying direct-part-marked symbols used on surgical and medical devices, and component parts.
Features & Benefits
Fully compliant with ISO/IEC 15426-1 and 15426-2, the verifier conformance standards, and ISO/IEC 15415 and 15416, the barcode print quality specifications. They also provide the data files needed to meet the requirements of the USA CFR 21 part II regulations.
Hardware
CCD sensor-based 2D barcode verifier. Aperture selectable to suit application standard. Wavelength of light 660 nm. The scan area and light source vary by model as explained below:
Model number | Field of view | Light wavelength | Aperture references | Symbols that can be verified |
---|---|---|---|---|
12000 | 25 mm x 18 mm | 660 nm | 03 – 20 | GS1 DataMatrix |
12500 | 37 mm x 25 mm | 660 nm | 03 – 20 | GS1 DataMatrix, GS1 QR Code, QR Code, GS1 DataBar, EAN/UPC |
12600 | 51 mm x 38 mm | 660 nm | 06 - 20 | GS1 DataMatrix, GS1 QR Code, QR Code, GS1 DataBar, EAN/UPC, GS1-128 |
12700 | 70 mm x 51 mm | 660 nm | 06 – 20 | GS1 DataMatrix, GS1 QR Code, QR Code, GS1 DataBar, EAN/UPC, GS1-128 |
12800 | 34 mm x 25.5 mm | 660 nm* | 03 – 20 | DPM - GS1 DataMatrix |
12000UV | 24 mm x 18 mm | UV | 03 – 20 | Special application for GS1 DataMatrix |
12000 OMNI | 150 mm x 112 mm | 660 nm | 03 – 20 | GS1 DataMatrix, GS1 QR Code, QR Code, GS1 DataBar, EAN/UPC, ITF-14, GS1-128 |
Axicon 12000 Series
Axicon 15000
1D/2D Verifier
Axicon 6525-S
Barcode Verifier
Axicon 7015
Barcode Verifier
Why Choose Axicon Verifiers?
* Illumination angles can be 30⁰, 45⁰, or 90⁰ to meet requirements for direct-part-marked symbols.
If it is necessary to verify QR Code symbols intended for scanning with a smartphone, these verifiers can be specified to use white light.
Connectivity
USB 2.0
System Requirements
Any currently supported version of Microsoft Windows.
Each verifier is supplied complete with the read-head, a CD with the Axicon verifier software, all cables, a quick start guide, a calibration card, and compliance certificates in a protective carry case.
A range of optional accessories is available:
Performance Qualification Test Kit
Many companies, especially those in the pharmaceutical sector, will be familiar with Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ) testing. These are tests designed to check that the relevant equipment has been installed correctly, that the equipment operates correctly, and then works correctly as intended.
Click here to view the PQ test kit page
Presentation Mount:
This is a purpose-built frame allowing for the Axicon 12000 to be used upside down, so making it much easier to verify barcodes on finished products, whatever their size or shape. It means the verifier does not need to be lifted or moved, and is very useful when it is in high use. This frame may also be physically attached to a bench to remove the risk of the verifier being dropped or knocked.
Tube or vial holder
This is to be used together with the presentation mount, and makes it much easier to achieve the consistently accurate verification of GS1 DataMatrix symbols on small tubes and vials.